| Item |
Performance Characteristics |
| Operating Temperature
Range |
-40 to +85℃ |
| Rated Working Voltage
Range |
10 to 50V DC |
| Nominal Capacitance
Range |
0.1 to 470μF |
| Capacitance Tolerance |
±20% (±10% on request) |
| Leakage Current |
I≤0.002CV or 0.3μA
whichever is greater measured after 2 minutes application
of reted working voltage at +20℃ |
| tanδ
(120Hz,+20℃)
|
| Working volage (V) |
10
|
16
|
25s
|
35
|
50
|
| tanδ (max) |
0.17
|
0.13
|
0.10
|
0.10
|
0.08
|
|
| High Temperature Loading |
Test conditions
Duration
Ambient temperature
Applied voltage
Post test requirements at +20℃
Leakage current
Capacitance change
tan δ |
: 500 huors
: +85℃
: Rated DC working voltage
:≤ Initial specified value
:≤ ±20% of initial measured value
:≤ 150% of initial specified value
|
|
|
| Shelf life |
Test conditions
Duration
Ambient temperature
Applied voltage
Post test requirements at +20℃
Leakage current
Capacitance change
tan δ |
: 500 huors
: +85℃
: Rated DC working voltage
:≤ Initial specified value
:≤ ±20% of initial measured value
:≤ 150% of initial specified value
|
*Pre-treament for measurements
Measurements shall be conducted after application of DC working
voltage for 30 minutes |