Item
|
Performance Characteristics
|
|
Operating Temperature Range
|
-40 to +85℃
|
|
Rate Working Range
|
4 to 50v DC
|
|
Nominal Capacitance Range
|
0.1 to 47μF
|
|
Capacitance Tolerance
|
±20%(120Hz,+20℃)
|
|
Leakage Current
|
I≤0.01cv or 3[μA]
whichever is greater measured after 2 minutes application of
rated
working voltage at +20℃.
|
|
tan δ(120Hz,+20℃)
|
| Working Voltage [V] |
4
|
6.3
|
10
|
16
|
25
|
35
|
50
|
| Tan δ max. |
0.35
|
0.24
|
0.20
|
0.16
|
0.14
|
0.12
|
0.10
|
|
|
Characteristics at low Temperature
|
Impedance ratio max. at 120Hz
| Working Voltage [V] |
4
|
6.3
|
10
|
16
|
25
|
35
|
50
|
| -25℃/+20℃ |
7
|
4
|
3
|
2
|
2
|
2
|
2
|
| -40℃/+20℃ |
15
|
8
|
6
|
4
|
4
|
3
|
3
|
|
|
High Temperature Loading
|
Test conditions
| |
|
| Duration |
:1000 hours |
| Ambient Temperature |
:+85℃ |
| Applied Voltage |
:Rated DC working voltage |
Post test requirements at +20℃
| |
|
| Leakage current |
:≤Initial specified value |
| Capacitance change |
:≤±20% of initial measured value |
| Tan δ |
:≤200% of initial measured value |
|
|
|
Shelf life
|
| Test conditions |
Post test requirements at
+20℃
Same limits for high temperature loading. |
| Duration |
:500 hours |
| Ambient Temperature |
:+85℃ |
| Applied voltage |
:(None) |
|
|