Item
|
Performance Characteristics
|
|
Operating Temperature Range
|
-40 to +85℃
|
|
Rated Working Voltage Range
|
4 to 50V DC
|
|
Nominal Capacitance Range
|
0.1 to 220μF
|
|
Capacitance Tolerance
|
±20%(120Hz,+20℃)
|
| |
I≤0.01CV or 3μA
whichever is greater measured after 2 minutes application
of rated working voltage at +20℃
|
|
Tan δ
(120Hz,+20℃)
|
| Working Voltage (V) |
4
|
6.3
|
10
|
16
|
25
|
35
|
50
|
| Tan δ (max) |
0.35
|
0.24
|
0.20
|
0.16
|
0.14
|
0.12
|
0.10
|
|
|
Characteristics at Low Temperature
|
Impedance ratio max at 120Hz
| Working Voltage [V] |
4
|
6.3
|
10
|
16
|
25
|
35
|
50
|
| -25℃/+20℃ |
7
|
4
|
3
|
2
|
2
|
2
|
2
|
| -40℃/+25℃ |
15
|
8
|
6
|
4
|
4
|
3
|
3
|
|
|
|
High Temperature Loading
|
Test conditions
Duration
Ambient temperature
Applied voltage
Post test requirements at
+20℃
Leakage current
Capacitance change
tan δ
|
: 1000 hours
: +85℃
: Rated DC working voltage
:≤ Initial specified value
:≤ ±20% of initial measured value
:≤ 200% of initial specified value
|
|
|
Shelf life
|
|
Test conditions
Duration
:500 hours
Ambient Temperature :+85℃
Applied Voltage (None)
Post test requirements at +20℃
Same limits for high temperature loading.
|
|