Item |
Performance Characteristics |
Operating Temperature Range |
-40 to +85℃ |
-25 to +85℃ |
Rated Working Voltage Range |
6.3 to 100V DC |
160 to 450V DC |
Nominal Capacitance Range |
0.47 to 15000μF |
0.47 to 220μF |
Capacitance Tolerance |
±20%(120Hz,+20℃) |
±20%(120Hz,+20℃) |
Leakage Current |
I≤0.01CV or 3μA after 2 minutes whichever is greater measured with rated working voltage applied at +20℃
|
I≤0.03CV+40μA
after 2 minutes application of rated working voltage at +20℃
|
Tan δ
(120Hz,+20℃) |
| Working Voltage |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
| Tan δ (max) |
0.22 |
0.20 |
0.16 |
0.14 |
0.12 |
0.10 |
0.09 |
0.08 |
| Working Voltage(V) |
160 |
200 |
250 |
350 |
400 |
450 |
| Tan δ (max) |
0.16 |
0.18 |
0.18 |
0.18 |
0.20 |
0.20 |
|
Ripple Current |
Refer to standard products table (120HZ,+85℃).
Correction factor for frequency
| Frequency [Hz] |
50/60 |
120 |
1k |
10k |
| Correction Factor (Multiplier) |
0.7 |
1 |
1.3 |
1.7 |
|
Low Temperature Characteristics |
Impedance ratio ma× at 120Hz
| Working Voltage [V] |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
| -25℃/+20℃ |
4 |
3 |
2 |
2 |
2 |
2 |
2 |
2 |
| -40℃/+25℃ |
8 |
6 |
4 |
4 |
3 |
3 |
3 |
3 |
| Working Voltage [v] |
160 |
200 |
250 |
350 |
400 |
450 |
| -25℃/+20℃ |
2 |
2 |
3 |
5 |
15 |
15 |
For capacitance value>1000μF,Add 0.5 per another 1000μF for -25℃/+25℃
Add 1.0 per another 1000μF for -40℃/+20℃ |
Impedance |
Ma×imum C-Z (rated cap.[μF] × Impedance [Ω] value at 10kHZ
| Working voltage [v] |
63 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
| C-Z max at +20℃ |
220 |
160 |
125 |
90 |
80 |
60 |
55 |
50 |
| C-Z max at -25℃ |
3000 |
1900 |
1300 |
800 |
650 |
560 |
500 |
450 |
| Working Voltage [V] |
160 |
200 |
250 |
350 |
450 |
| C-Z max at +20℃ |
100 |
140 |
150 |
170 |
270 |
| C-Z max at -25℃ |
2400 |
2500 |
3100 |
3500 |
12000 |
|
| High Temperature Loading |
Test conditions
Duration
Ambient temperature
Applied voltage
Post test requirements at +20℃
Leakage current
Capacitance change
tan δ |
: 10000 hours
: +85℃
: rated DC working voltage
:≤ Initial specified value
:≤ ±20% of initial measured value
:≤ 150% of initial specified value
|
|