Item
|
Performance Characteristics
|
|
Operating Temperature Range
|
-40 to +85℃
|
-25 to +85℃
|
|
Rated Working Voltage Range
|
6.3 to 100V DC
|
160 to 450V DC
|
|
Nominal Capacitance Range
|
0.47 to 15000μF
|
0.47 to 220μF
|
|
Capacitance Tolerance
|
±20%(120Hz,+20℃)
|
|
Leakage Current
|
I≤0.01CV or 3[μA] after 2
minutes whichever is greater measured with rated
working voltage applied at +20℃
|
I≤0.03CV +40μA
after 2 minutes application of rated
working voltage at +20℃
|
|
tanδ(120Hz,+20℃)
|
|
Working Voltage(V)
|
6.3
|
10
|
16
|
25
|
35
|
50
|
63
|
100
|
|
tanδ (max)
|
0.22
|
0.20
|
0.16
|
0.14
|
0.12
|
0.10
|
0.09
|
0.08
|
|
Working Voltage [V]
|
160
|
200
|
250
|
350
|
400
|
450
|
|
tanδ
max
|
0.16
|
0.18
|
0.18
|
0.20
|
0.20
|
0.20
|
For capacitance value >1000μF,add
0.02 per another 1000μF.
|
|
Ripple Current
|
Refer to standard products table (120Hz,+85℃).
Correction factor for frequency
|
Frequency [Hz]
|
50/60
|
120
|
1K
|
10K
|
|
Correction Factor (Multiplier)
|
0.7
|
1
|
1.3
|
1.7
|
|
|
Low Temperature Characteristics
|
Impedance ratio max. at 120Hz
| Working Voltage [V] |
6.3
|
10
|
16
|
25
|
35
|
50
|
63
|
100
|
| -25℃/+20℃ |
4
|
3
|
2
|
2
|
2
|
2
|
2
|
2
|
| -40℃/+20℃ |
8
|
6
|
4
|
4
|
3
|
3
|
3
|
3
|
| Working Voltage [V] |
160
|
200
|
250
|
350
|
400
|
450
|
| -25℃/+20℃ |
2
|
2
|
3
|
5
|
15
|
15
|
For capacitance value > 1000μF:
Add 0.5 per another 1000μF for -25℃/+25℃.
Add 1.0 per another 1000μF for -40℃/+20℃.
|
|
Impedance
|
Maximum C-Z (rated cap-[μF] × Impedance [Ω]) value
at 10kHz
| Working voltage [V] |
63 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
| C-Z max. at +20℃ |
220 |
160 |
125 |
90 |
80 |
60 |
55 |
50 |
| C-Z max. at +25℃ |
3000 |
1900 |
1300 |
800 |
650 |
560 |
500 |
450 |
| Working Voltage [V] |
160 |
200 |
250 |
350 |
450 |
| C-Z max. at +20℃ |
100 |
140 |
150 |
170 |
270 |
| C-Z max. at +25℃ |
2400 |
2500 |
3100 |
3500 |
12000 |
|
| High Temperatrue Loading |
Test Conditions
Duration
: 2000 hours
Ambient Temperature
: +85℃
Applied Voltage
: Rated DC working voltage.
Post test requirements at +20℃
Leakage current
: ≤ Initial specified value.
Capacitance change
: ≤ ±20% of initial measured value.
tan δ
: ≤ 150% of initial specified value . |
| Shelf Life |
Test conditions
Duration
: 500 hours
Ambient Temperature : +85℃
Applied Voltage
: (None)
Post test requirements at +20℃
Same limits for high temperature loading.
|