Item
|
Performance Characteristics
|
|
Rated Working Voltage Range
|
6.3 to 100V DC
|
160 to 450V DC
|
|
Operating Temperature Range
|
-40 to +105℃
|
-25 to +105℃
|
|
Nominal Capacitance Range
|
0.1 to 15000μF
|
0.47 to 220μF
|
|
Capacitance Tolerance
|
±20%(120Hz,+20℃)
|
|
Leakage Current
|
I≤0.01CV or 3 [μA]
|
I≤0.03CV or 40 [μA]
|
|
after 2 minutes application of rated working
voltage at +20℃
|
|
tan σ
(120Hz,+20℃)
|
| Working voltage [V] |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
| tan σ
max. |
0.22 |
0.20 |
0.16 |
0.14 |
0.12 |
0.10 |
0.09 |
0.07 |
| Working voltage [V] |
160 |
200 |
250 |
350 |
400 |
450 |
| tan σ max. |
0.15 |
0.15 |
0.15 |
0.20 |
0.24 |
0.24 |
For
capacitance value >1000uF,add 0.02 per another 1000uF
|
|
Maximum Permissible Ripple Current
|
Refer to standard peoducts table (120Hz,+105℃) Correc tion factor
frepuency
|
Freq.[Hz]
W.V.[V.DC] CAP[uF]
|
60
|
120
|
1k
|
10k
|
100k
|
|
6.3~50
|
0.1~330
|
0.85
|
1
|
1.30
|
1.40
|
1.55
|
|
470~3300
|
0.95
|
1
|
1.15
|
1.20
|
1.25
|
|
≥4700
|
0.95
|
1
|
1.10
|
1.20
|
1.20
|
|
63~100
|
0.47~33
|
0.75
|
1
|
1.55
|
1.65
|
1.80
|
|
47~220
|
0.75
|
1
|
1.40
|
1.60
|
1.65
|
|
≥330
|
0.80
|
1
|
1.30
|
1.35
|
1.40
|
|
≥160
|
1~220
|
0.70
|
1
|
1.30
|
1.70
|
1.70
|
|
| Low Temperature Characteristics |
Impedance ratio max.at
120Hz.
|
Working Voltage[V]
|
6.3
|
10
|
16
|
25
|
35
|
50
|
63
|
100
|
|
-25℃/+20℃
|
4
|
3
|
2
|
2
|
2
|
2
|
2
|
2
|
|
-40℃/+20℃
|
8
|
6
|
4
|
3
|
3
|
3
|
3
|
3
|
|
Working Voltage[V]
|
160
|
200
|
250
|
350
|
400
|
450
|
|
-25℃/+20℃
|
3
|
3
|
3
|
6
|
6
|
15
|
For capaciance value > 1000uF: Add 0.5 per another 1000uF
for -25℃/+20℃
Add 1.0 per another 1000uF for -40℃/+20℃ |
|
| High Temperature Loading |
| Test Conditions |
|
| Duration |
1000 hours |
| Ambient Temperature |
+105℃ |
| Applied Voltage |
DC voltage with maximum
permissible ripple current specified at +105℃(Sum of the DC
voltage and super-imposed peak AC voltage for maximum permissible
ripple current should be equal to rated DC working voltage). |
| Post test requirements
at +20℃ |
| Leakage Current |
≤ Initial specified
value |
| Capacitance change |
≤±20% of initial
measured value |
| tanδ |
≤200% of initial
specified |
|
| Shelf Life |
| Test Conditions |
Post test requirements at +20℃ |
| Duration |
Same limits for high temperatute |
| Ambient Temperature |
loading. |
| Applied Voltage |
|
|